The W2 serial port is configured for 9600 baud, 8 databits, 1 stopbit, no handshake.
String Length String Length 3 chars.
Notes Notes Adjust to your liking.
String Length String Length 3 chars.
Response Response [7S;][8M;][9F;]
String Length 3 chars. String Length 4 chars. EEPROM: Yes
String Length String Length 24 chars.
-
String Length 5 chars. String Length
String Length 3 chars. String Length
String Length 3 chars. String Length
Toggles Sensor "Search" mode.
Elecraft W2 Serial Interface Commands
Revision D, April 12, 2010. Applies to firmware rev 1.00 or higher.
Copyright © 2009 - 2010, Elecraft, Inc.; All Rights Reserved
The W2 responds to commands for data supplied by the external system. Nothing is sent until a command is received by the
W2. These requests are in the form of a single letter as shown below. The user sends a single character and receives one data
string in response. The semicolon (;) is an end-of-string identifier, and will be at the end of every return string. The strings vary
in length. Use the table below to determine the output from your command input.
"[" lowers value, "]" raises it.
Adjusts SWR Alarm trip point
Only works with two sensors.
Range is 1.1 to 5.0 (implied decimal).
Output Sensor Calibration values.
Sets the active sensor to Autorange.
E l e c r a f t • w w w . e l e c r a f t . c o m • 8 3 1 - 7 6 3 - 4 2 1 1
Adjust calibration of active sensor.
Matches function of "Range" button.
Sets active sensor to one range.